Hazardous Location Lighting D Series Bottom View Hazardous Location Lighting D Series Side View

Products - Hazardous

Hazardous Location Lighting D Series

Uses

High Bay, Floodlight

Applications

  • Oil Refineries & Fuel Depots
  • Marine Vessels
  • Chemical Production & Processing
  • Grain Processing
  • Mines
  • Distilleries
  • Other high humidity, high temperature, dusty locations

Features

  • Available in 2,800 to 25,200 lumens
  • High efficacy: up to 140lm/W
  • Surface mounting and pendant installation
  • Wide and narrow optics for uniform illumination
  • Copper free aluminum
  • High vibration resistance

Classifications

  • NEMA 4X, IP66
  • UL1598 / UL1598A / UL844
  • CSA C22.2 No.137 / No.250.0
  • Class I, Division 1, Groups C, D
  • Class I, Division 2, Groups A, B, C, D
  • Class II, Division 1 & 2, Groups E, F, G
  • Class III
  • Marine and Wet Locations
  • IECEX
  • ATEX

Specifications

Product Number EL-HZ-20W D2YZDA EL-HZ-40W D2YZDA EL-HZ-60W D2YZDA EL-HZ-80W D2YZDA EL-HZ-80W DYZDA EL-HZ-100W DYZDA EL-HZ-150W DYZDA EL-HZ-180W DYZDA
Wattage 20 40 60 80 100 150 180
CCT 4000K - 5700K
Voltage AC100-277V or AC200-480V AC100-277V AC100-277V or AC200-480V
Lumens 2800 5600 8400 11200 14000 21000 25200
Working Hours 5 Years
CRI 70

"D, D2" = Product series
"Z" = CCT, from 4000~5700K

"Y" = D or N: Dimmable or non-dimmable
"D" = Beam angle: 40°, 60°, 90°, 120°

Mechanical Information

AC100-277V models AC200-480V models
D Series Size (in) 15.7 × 11.3 × 10
D2 Series Size (in) 11.6 × 11.6 × 9.55

Download Catalog Sheet »